Electronic ballast test marks
110 ⊥ is overheating protection sign, that is at any point of the exterior temperature of the electronic ballasts with this sign won't be over 110⊥ in any conditions, which can be safely used with wood exterior lamps and plastic lamps.
is the equipment and product quality safety sign in Europe union membership countries. The EASEIC electronic ballasts with this sign can indicate that this product accords with the corresponding criterion of CE certification requirements.
is Europe currency certification sign, ENEC10. This 10 indicates that the product accord with the requirement of ENEC that the third party independent test organization is Germany VDE, that is the certification of the product is issued by VDE. The EASEIC electronic ballasts with this sign indicate that this product accord with the corresponding criterion of EN60928 and EN60929 standards.
is Europe electromagnetism compatibility certification sign. The EASEIC electronic ballasts with this sign indicate that this product has fulfilled the corresponding standard of Europe in anit-electomagnetism interfere, control electromagnetism interfere output as well as humorous content control and other aspects.
is the early America safety certification sign, which at present has become the safety certification sign worldwide The EASEIC electronic ballasts with this sign indicate that this product accords with the corresponding criterion of UL safety certification and has got this certification.
is China compulsion product certification sign.The EASEIC electronic ballasts with this sign indicate that this product accords with the corresponding criterion requirements of GB15143,GB17743-99,GB17625.1-98 and has got this certification.
is digital addressable lighting interface sign. The EASEIC electronic ballasts with this sign indicate that the control interface of this product accords with the corresponding criterion requirements of DALI.
Energy capability index EEI. It indicates the energy saving grade of the electronic ballasts.
is the highest grade of energy capability that EASEIC dimmable fluorescent lamp electronic ballasts and dimmable HID lamp electronic ballasts can reach.
is the highest grade of energy capability that the low energy consumption EASEIC professional fluorescent lamp electronic ballasts and professional HID lamp electronic ballasts can reach.
is the energy capability grade that the normal energy consumption EASEIC professional fluorescent lamp electronic ballasts and professional HID lamp electronic ballasts can reach.
Standards
EN 55015 |
CISPR 15 Radio disturbances < 30 Mhz |
EN 55022 |
CISPR 22 Radio disturbances > 30 Mhz |
EN 60598-2-22;IEC 60598-2-22 |
Particular requirements for luminaires for emergency lighting |
EN 60920 (EN 61347-2-8);IEC 60920 (IEC 61347-2-8) |
Ballasts for tubular fluorescent l amps 每 general and safety requirements |
EN 60921; IEC 60921 |
Ballasts for tubular fluorescent lamps 每 performance requirements |
EN 60922 (EN 61347-2-9);IEC 60922 (IEC 61347-2-9) |
Ballasts for discharge lamps 每 general and safety requirements |
EN 60923; IEC 60923 |
Ballasts for discharge lamps 每 performance requirements |
EN 60924; IEC 60924(EN 61347-2-4; EN 61347-2-7); (IEC 61347-2-4; IEC 61347-2-7) |
DC supplied electronic ballasts for tubular fluorescent lamps 每general and safety requirements |
EN 60925; IEC 60925 |
DC supplied electronic ballasts for tubular fluorescent lamps 每 performance requirements |
EN 60928 (EN 61347-2-3); IEC 60928 (IEC 61347-2-3) |
AC supplied electronic ballasts for tubular fluorescent lamps 每general and safety requirements |
EN 60929; IEC 60929 |
AC supplied electronic ballasts for tubular fluorescent lamps 每 performance requirements |
EN 61000-3-2; IEC 61000-3-2 |
Harmonic current emissions |
EN 61347-2-3; IEC 61347-2-3 |
Particular requirements for AC supplied electronic ballasts for fluorescent lamps |
EN 61347-2-4; IEC 61347-2-4 |
Particular requirements for DC supplied electronic ballasts for general lighting |
EN 61347-2-7; IEC 61347-2-7 |
Particular requirements for DC supplied electronic ballasts for emergency lighting |
EN 61347-2-8; IEC 61347-2-8 |
Particular requirements for ballasts for fluorescent lamps |
EN 61347-2-9; IEC 61347-2-9 |
Particular requirements for ballasts for discharge lamps |
EN 61547; IEC 61547 |
EMC immunity requirements |
EN 61558; IEC 61558 |
Safety of power transformers |
acc. VDE 0108 |
Suitable for emergency lighting installations |
IEC 68-2-64 |
Environmental testing 每 test Fh: Vibration, broad-band random (digital control) |
IEC 68-2-29 |
Basic environmental testing procedures 每 test Eb: Bump |
IEC 68-2-30 |
Basic environmental testing procedures 每 test Db: Damp heat, cyclic (12+12-hour cycle) |
UL 935 |
Fluorescent-Lamp Ballasts |
ANSI C62.41 |
Category A Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits |
ANSI C82.11 |
High-Frequency Fluorescent-Lamp Ballast |
GB/T15144-94 |
AC supplied electronic ballasts for tubular fluorescent lamps 每 performance requirements |
GB15143-94 |
AC supplied electronic ballasts for tubular fluorescent lamps 每general and safety requirements |
GB17625.1-1998 |
The limits for the harmonic current emissions caused by low-voltage electrical and electronic equipments (equipment input current ≒ 16A per phase) |
GB17743-1999 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
GB17263-2002 |
Self-ballasted lamps for general lighting service -performance requirements | |